Power
90-264 VAC, 47/63 Hz
Temperature
0°C to -40°C (32°F to 104°F)
Humidity
15% - 90% non-condensing
Control Unit
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
- Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded electrical outlet not controlled by a switch, using supplied 7-foot.
- Operating temperature of room: 32 to +104 F (0 to +40 C), not in direct sunlight.
- Humidity 15% to 90% non-condensing.
For proper ventilation and easy replacement of modules, provide the following maximum clearance around the control units:
- 5-slot carrier: 1 foot (0.3 meter) clearance at the top and sides, and 2 feet (0.6 meter) clearance at the front and bottom.
- 2-slot carrier or stand-alone PARTNER® Advanced Communications System processor module: 1 foot (0.3 meter) clearance at the front, top, and right side, and 2 feet (0.6 meter) clearance at the bottom and left side.
- Locate in an area free of excess moisture, corrosive gases, dust, and chemicals.